B A C K
STAINLESS STEEL COMPARTMENTS
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Floor anchored, overhead braced pilasters (Metropolitan style).
B. Floor anchored pilasters (New Yorker style).
C. Ceiling hung pilasters (Empire style).
D. Floor to ceiling pilasters (Gramercy style).
E. Urinal screens.
1.2 QUALITY ASSURANCE
A. Source: Provide partitions and screens which are the products of
one manufacturer.
B. Coordination: Coordinate related work such as concealed blocking
to ensure proper location and quantity.
1.3 SUBMITTALS
A. Product Data: Submit manufacturer’s product data, installation details,
and catalog cuts for partitions, hardware and accessories.
B. Shop Drawings: Provide shop drawings for field measurements, fabrication,
installation and erection of all parts of the work.
C. Manufacturer’s Installation Instructions: Provide details of hardware
locations and drilling dimensions.
1.4 FIELD MEASUREMENTS
A. Verify that field measurements are as indicated on shop drawings.
Advise manufacturer of any changes.
1.5 DELIVERY, STORAGE AND HANDLING
A. Deliver materials and products in unopened factory labeled packages.
Store and handle in strict compliance with manufacturer’s instructions
and recommendations. Protect from all possible damage. Inspect cartons
at the time of delivery and advise carrier of any damage immediately.
1.6 MATERIAL
A. Panels, doors, pilasters, urinal screens and shoes to be made of
#304 stainless steel with a #4 polish finish. All parts to be protected
against scratching with a vinyl coating which is to be removed after installation.
PART 2 - PRODUCTS
2.01 ACCEPTABLE MANUFACTURERS
A. Knickerbocker Partition Corporation
2.02 MATERIALS AND PRODUCTS
A. Panels, Urinal Screens and Doors: Shall be 1” thick, constructed
from two sheets of 20 gauge type #304 stainless steel with a #4 finish.
Sheets to be formed and cemented under pressure to a structural vermin-proof
honeycomb core. Formed sheets shall be welded together at intervals around
entire perimeter to ensure a rigid one-piece integral unit. All edges shall
be bound with a 20 gauge stainless steel interlocking molding and formed
with stainless steel corner clips.
B. Metropolitan Pilasters: Shall be 1-1/4” thick, constructed of two
sheets of 20 gauge type #304 stainless steel with #4 finish. Sheets to
be formed and cemented under pressure to a structural vermin-proof honeycomb
core. Formed sheets shall be welded together at intervals around entire
perimeter to ensure a rigid one-piece integral unit. All edges shall
be bound with an 18 gauge stainless steel interlocking molding. Bottom
of pilasters shall have adjustable floor anchor, with leveling device,
anchor studs and locking nuts to firmly secure pilasters to floor. This
entire assembly to be concealed with a 3” high stainless steel plinth,
secured in place with concealed clips.
C. Headrail: Partitions and pilasters, when set in place, shall be securely
braced with 1” x 2” anodized aluminum anti-grip headrail bracing, inserted
and securely fastened into the top of the pilasters with theft-resistant
screws.
D. New Yorker Pilasters: Shall be 1-1/4” thick, constructed of two sheets
of 18 gauge, type #304 stainless steel with #4 finish. Sheets to be formed
and cemented under pressure to a vermin-proof honeycomb core. Formed sheets
shall be welded together at intervals around entire perimeter to
ensure a rigid one-piece integral unit. All edges shall be bound with an
18 gauge interlocking molding and formed with stainless steel corner clips.
Pilasters, when set in place, shall be securely anchored to concrete sub-floor
by means of 3/8” diameter cadmium plated bolts with a minimum penetration
of two inches, secured rigidly into concrete slab with expansion shields
and secured to the pilasters through a one-piece 12 gauge channel integrally
welded to the pilasters. This entire assembly to be concealed with a 3”
high stainless steel plinth, secured in place with concealed clips.
E. Empire Pilasters: Shall be 1-1/4” thick, constructed of two sheets
of 18 gauge, type #304 stainless steel with #4 finish. Sheets to be formed
and cemented under pressure to a vermin-proof honeycomb core. Formed sheets
shall be welded together at intervals around entire perimeter to ensure
a rigid one-piece integral unit. All edges shall be bound with an 18 gauge
interlocking molding and formed with stainless steel corner clips. Pilasters,
when set in place, shall be securely anchored to overhead carrying member
(overhead structural steel members to be furnished, installed and drilled
by others) by means of 3/8” diameter cadmium plated bolts through a one-piece
12 gauge channel integrally welded to the pilaster. This entire assembly
to be concealed with a 3” high stainless steel plinth, secured in place
with concealed clips.
F. Gramercy Pilasters: Shall be 1-1/4” thick, constructed of two sheets
of 20 gauge, type #304 stainless steel with #4 finish. Sheets to be formed
and cemented under pressure to a vermin-proof honeycomb core. Formed sheets
shall be welded together at intervals around entire perimeter to ensure
a rigid one-piece integral unit. All edges shall be bound with an 18 gauge
stainless steel interlocking molding. Both the top and the bottom of the
pilasters shall have adjustable anchor and leveling devices. Anchor studs
and locking nuts designed to firmly secure the pilaster to the floor and
ceiling. Both assemblies to be concealed with 3” high stainless steel plinths,
secured in place with concealed clips.
G. Hardware and Fittings: Panels and pilasters shall be attached to
one another and/or to walls with Zamac chrome plated brackets. Doors shall
be equipped with Knickerbocker Ever Life Spring Activated Non-Rising hinges.
Top Hinge Pivot Door Bracket to be recessed and inset into edge of door,
approximately 2” below the top with a pivot pin, operating on a self-lubricating
bushing, mounted within the door structure, supported both above and below
the pivot bracket. Operation of door shall be controlled by opposing cams
under spring tension, mounted on a fixed vertical pintle. Hinges to be
adjustable to permit door to rest at any angle, or to hold door open or
closed when not latched. Hinges shall operate without raising or lowering
the door on a fixed horizontal plane. Each door shall be equipped with
stop and keeper, combination coat hook and bumper and concealed latch,
featuring a latch cover which permits access to the compartment in case
of emergency. Handicap door to be equipped with Knickerbocker Partition
Corporation Lever Handle. Design to comply with ADA requirements. Hinge
bracket and stops shall have clamp flanges to transmit the strain of door
closing to the pilaster. All hardware shall be heavy one-piece, non-ferrous
“Zamac” casting, heavily chrome plated. Hinges, stop and keeper, pilaster
and panel brackets shall be thru-bolted with sex bolts having theft-resistant
heads.
PART 3 - EXECUTION
3.01 INSTALLATION
A. Install partitions secure, rigid, plumb and level in accordance with
manufacturer’s instructions.
B. Maintain manufacturer’s recommended spacing between wall and panels
and between wall and pilasters.
C. Equip each door with hinges, concealed lock, coat hook and bumper,
door strike and keeper. Outswing doors shall have a door pull and wall
bumper.
3.02 ADJUSTMENT
A. Adjust operating parts to work easily, smoothly and correctly.
B. Adjust and align hardware to uniform clearance at vertical edge of
doors, not exceeding 3/16 inch.
C. Adjust hinges to position inswing doors at a 30 degree angle to pilasters
and outswing doors to a fully closed position.
|